Numbers of fixing in concrete and solid material
anchor diameter |
M 8 |
M 10 |
M 12 |
M 16 |
M 20 |
M 24 |
M 30 |
bore hole diameter [mm] |
10 |
12 |
14 |
18 |
24 |
28 |
35 |
setting depth [mm] |
80 |
90 |
110 |
125 |
175 |
210 |
280 |
165 ml |
41 |
25 |
15 |
8321 |
|
235 ml |
61 |
38 |
23 |
12 |
5 |
3 |
1 |
|
280 ml |
74 |
46 |
27 |
15 |
6 |
4 |
2 |
|
300 ml |
80 |
49 |
30 |
16 |
6 |
4 |
2 |
|
330 ml |
88 |
54 |
33 |
17 |
7 |
4 |
2 |
|
345 ml |
93 |
57 |
34 |
18 |
7 |
4 |
2 |
|
410 ml |
103 |
63 |
38 |
20 |
8 |
5 |
2 |
|
385 ml |
104 |
64 |
39 |
21 |
8 |
5 |
2 |
|
410 ml |
111 |
69 |
41 |
22 |
9 |
5 |
3 |
|
880 ml |
247 |
153 |
92 |
49 |
20 |
12 |
6 |
|
910 ml |
256 |
158 |
95 |
51 |
20 |
12 |
6 |
|
Numbers of fixing in hollow brick
anchor diameter |
M 8 |
M 10 |
M 12 |
M 16 |
bore hole diameter [mm] |
10 |
12 |
14 |
18 |
approved sleeve |
13x100 |
15x100 |
- |
- |
standard sleeve |
13x85 |
13x85 |
13x85 |
18x85 |
standard |
165 ml |
12 |
12 |
12 |
6 |
approved |
165 ml |
11 |
8 |
|
- |
standard |
235 ml |
19 |
19 |
19 |
10 |
approved |
235 ml |
16 |
12 |
- |
- |
standard |
280 ml |
23 |
23 |
23 |
12 |
approved |
280 ml |
19 |
14 |
- |
- |
standard |
300 ml |
24 |
24 |
24 |
13 |
approved |
300 ml |
21 |
16 |
- |
- |
standard |
345 ml |
28 |
28 |
28 |
15 |
approved |
345 ml |
24 |
18 |
- |
- |
standard |
410 ml |
31 |
31 |
31 |
16 |
approved |
410 ml |
27 |
20 |
- |
- |
standard |
410 ml |
34 |
34 |
34 |
18 |
approved |
410 ml |
29 |
22 |
- |
- |